Spray Foam Types

(click on the images below to learn more)

California Building Code CRC Code 806.5

 

unvented attic and unvented enclosed rafter assemblies

Unvented attic assemblies (spaces between the ceiling joists of the top story and the roof rafters) and unvented enclosed rafter assemblies (spaces between ceilings that are applied directly to the underside of roof framing members/rafters and the structural roof sheathing at the top of the roof framing members/rafters) shall be permitted if all the following conditions are met:

1. The unvented attic space is completely contained within the building thermal envelope.


2. No interior Class I vapor retarders are installed on the ceiling side (attic floor) of the unvented attic assembly or on the ceiling side of the unvented enclosed rafter assembly.


3. Where wood shingles or shakes are used, a minimum 1/ - 4 inch (6 mm) vented air space separates the shingles or shakes and the roofing underlayment above the structural sheathing.


4. In California Climate Zones 14 and 16, any air-impermeable insulation shall be a Class II vapor retarder, or shall have a Class III vapor retarder coating or covering in direct contact with the underside of the insulation. See Title 24, Part 6, Figure 100.1-A-California Climate Zones.

5. Either Items 5.1, 5.2 or 5.3 shall be met, depending on the air permeability of the insulation directly under the structural roof sheathing. No insulation shall be required when roof tiles, wood shingles or wood shakes, or any other roofing system using battens and no continuous underlayment is installed. A continuous layer shall be considered to exist if sheathing, roofing paper or any continuous layer which has a perm rate of no more than one perm under the dry cup method.

5.1. Air-impermeable insulation only. Insulation shall be applied in direct contact with the under- side of the structural roof sheathing.

5.2. Air-permeable insulation only. In addition to the air-permeable insulation installed directly below the structural sheathing, rigid board or sheet insulation with an R-value of R-4 shall be installed directly above the structural roof sheathing for condensation control. 

5.3.  Air-impermeable and air-permeable insulation. The air-impermeable insulation shall be applied in direct contact with the underside of the structural roof sheathing for condensation control. The air-permeable insulation shall be installed directly under the air-impermeable insulation.

5.4.  Where preformed insulation board is used as the air-impermeable insulation layer, it shall be sealed at the perimeter of each individual sheet interior surface to form a continuous layer. 


 

Insulate sB, INC dba Insulate Socal  <>  info@insulatesocal.com  <> License No. 963692 <> All Rights Reserved © 2018

     Whether you need to simply deliver a comfortable, affordable home environment for your clients or solve design challenges to give them the home of their dreams, Icynene spray insulation is the clear choice for insulating a house. Icynene spray insulation is an air barrier that seals cracks and crevices other insulation's miss, even in hard-to-insulate spaces. The results are unique and lasting benefits, like improved indoor air quality, moisture management, sound dampening — and energy savings.


      So dramatic, Icynene spray insulation pays for itself in just three to four years on average. Energy efficiency is a top consideration among homeowners in the market for insulation. Icynene spray foam insulation helps you give them exactly what they want. In fact, Icynene can help reduce energy bills by up to 50%.  Savings that exceed insulation costs and the investment then continues to pay off in the form of monthly savings for the life of the home.

Efficiency.

Spray Foam is proven performancE